.The traditional way of shortening the coasting time of a commutator motor
following turn-off is to consume current from the still-rotating armature.
The machine
A. Operation from a single-phase power line.
B. Operation from a two-phase power source.

FIG. 19 Required voltage when constant-torque output is desired from
a Slo-Syn motor. Superior Electric Co.

FIG. 20 Switching logic for sequential stepping of the Slo-Syn motor.

FIG. 21 Sequential stepping-logic for bifilar Slo-Syn motor and single-ended
power supply.
then becomes a generator, and the electrical energy it delivers is derived
from the kinetic energy stored in its rotating members. Rotation is therefore
quickly decelerated, and the motor is brought to a standstill in much
shorter time than it would be from windage and bearing friction (see
Fig. 24). Non-commutator motors, how ever, are not suitable for this
method of dynamic braking.
Two-phase and three-phase induction motors can be dynamically braked
by “plugging,” that is, by attempting reverse rotation. This is accomplished
in these polyphase motors by transposing power-line connections to one
phase of the motors stator winding. Because the permanent-capacitor,
split-phase motor is, in essence, a two-phase machine, it too can be
dynamically braked by the ordinary reversing technique. Of course, all
motors braked by attempted reversal must be disconnected from the power
line before actual reverse rotation occurs. The resistance-start induction
motor, or what is loosely referred to as a “split-phase” motor is not
readily braked by transposition of its windings, nor is the capacitor-start
induction motor. The basic idea is that those motors, which ordinarily
should not be reversed until the shaft is at rest, should not be subjected
to the “plugging” techniques.
All ac motors with squirrel-cage rotors can be dynamically braked by
injecting dc into one, or more, of their windings following disconnect
from the ac power line. In essence, such machines then become separately
excited dc generators with shorted armatures. Such braking can be very
effective, and there is no tendency for reverse rotation. Immediately
after standstill is achieved, the dc should be disconnected to prevent
heating of the stator winding(s).

FIG. 22 Dynamic-braking technique for ac motors with squirrel-cage rotors.
A more sophisticated method for accomplishing such braking is to dump
the electric energy stored in a capacitor into one or more stator windings
of squirrel- cage motors. The circuit shown in FIG. 22 is applicable
to shaded-pole motors and all other ac motors with squirrel-cage rotors,
providing they are not too large—V hp is perhaps a practical limit because
of the inordinate capacitor size required for larger machines. Depending
on the motor size and the deceleration desired, capacitors up to hundreds
of microfarads are feasible for many braking requirements. Diode D1 can
be a silicon rectifier with a current rating of several amperes. Resistor
R1 can be a two-watt composition resistor of about 50 k or so.
Synchronous motors can usually be braked by the application of dc to
the stator, but the decelerating mechanism is somewhat different from
that of induction motors. Empirical investigation is often required for
optimum results. A possible ad vantage attending dynamic braking of synchronous
motors is their ability to lock in position once brought to a standstill.
This “holding” behavior is most pronounced in the reluctance synchronous
motor.
|